Test Name: Urinalysis with Microscopy, Culture if >5 WBC's/hpf

Test Code(s): UACULT / HCUACULT

CPT Code(s): 81001

Test Description: Test Component:

Urine dipstick, urine microscopic findings, and, if greater than 5 WBC's are seen per high power field on microscopic exam, a urine culture will be performed.


Methodology: Automated Urine Chemistry and Microscopy Analyzer

Days Performed: Daily, 24 hours.

Turnaround Time: Stat: 1 hour.
Routine: 4 hours.


Specimen Requirements

Specimen: Urine

Collection Instructions: First morning void preferred. Refrigerate if transportation to lab is delayed.  Indicate whether specimen is midstream, indwelling catheter, single catheter or other method of collection. For midstream urine collection instructions refer to Health Facts for you - Male HF #4247, Female HF # 4236 located on UConnect.

Collection Container: Preferred: Sterile screw cap container

Collection Volume: Preferred: 10 mL
Pediatrics: 3 mL

Sample Analyzed: Urine aliquot

Volume Required: Preferred: 10 mL
Pediatrics: 3 mL

Specimen Transport: Transport specimen to the laboratory immediately. Transport with coolant pack if coming from outreach location.  

Unacceptable Criteria: Samples held at room temperature for more than 2 hours or samples refrigerated for more than 24 hours are not acceptable.

Stability: Ambient: 2 hours
Refrigerated: 24 hours
Frozen: Not acceptable


Interpretation

Reference Interval:

Age 0 days and up:

 

Dipstick:

 Specific Gravity  1.005-1.035
 pH  5.0-8.0
 Protein  Negative
 Glucose  Negative
 Ketones  Negative
 Hemoglobin  Negative
 Bilirubin*  Negative     
 Leukocyte Esterase  Negative
 Nitrite  Negative
 Urobilinogen  0.2, 1.0, <2.0 mg/dL

 

Microscopic Findings:

WBC 0-5/hpf
RBC 0-2/hpf
Bacteria Not seen
Squamous Epithelial cells 0-2/hpf

Renal Epithelial cells

Not seen or less than 1/hpf
Crystals

Few calcium oxalate, few amorphous urates or phosphates

Casts 0-4 hyaline casts/lpf